Discover VRLA AGM Float Standby Battery 6V & 12V
Discover VRLA AGM Float Standby Battery β 6V & 12V
SKU: D650-F1 | D680-F1 | D6120-F1 | D1213-F1 | D1250-F1 | D1272-F1 | D1290-F2 | D12120-F2 | D12180-M5 | D12350-M6
The Discover VRLA AGM Float Standby battery is a maintenance-free sealed lead-acid battery built for reliable backup power in everyday applications. It's a good fit for medical devices, security systems, emergency lighting and other standby uses where downtime isn't an option. It has an up to 5-year design life, and its low self-discharge gives it a long shelf life.
- AGM, VRLA technology β maintenance-free, non-spillable and no-gassing
- Available in 10 sizes from 1.3 AH to 35 AH (20-hour rate)
- Up to 5-year design life
- 99% gas recombination extends battery life
- Flame retardant UL94:V0 ABS case and cover available
What It Is
The Discover VRLA AGM Float Standby battery is a valve-regulated lead-acid (VRLA) battery that uses absorbed glass mat (AGM) technology. The battery is sealed, so it needs no watering or electrolyte checks.
It is made for float, or standby, service, where the battery stays on a charger and is ready to supply power when the main power goes out. It works across a wide range of temperatures and handles the cold better than flooded or gel batteries.
Choose Your Model
All models share the same AGM technology, features and charging method. They differ in voltage, size, capacity and terminal.
6V Models
| SKU | Capacity 20 Hr / 10 Hr / 5 Hr / 1 Hr | Dimensions (L x W x H) | Total Height | Weight | Terminal |
|---|---|---|---|---|---|
| D650-F1 | 5 / 4.7 / 4.3 / 3.2 AH | 2.76" x 1.85" x 3.98" | 4.2" | 1.76 lbs | F1 |
| D680-F1 | 8 / 7.6 / 6.9 / 4.9 AH | 5.94" x 1.34" x 3.70" | 3.9" | 2.65 lbs | F1 |
| D6120-F1 | 12 / 11.4 / 10.2 / 7.5 AH | 5.94" x 1.97" x 3.70" | 3.9" | 3.86 lbs | F1 |
12V Models
| SKU | Capacity 20 Hr / 10 Hr / 5 Hr / 1 Hr | Dimensions (L x W x H) | Total Height | Weight | Terminal |
|---|---|---|---|---|---|
| D1213-F1 | 1.3 / 1.15 / 1.1 / 0.81 AH | 3.82" x 1.69" x 2.05" | 2.3" | 1.21 lbs | F1 |
| D1250-F1 | 5 / 4.7 / 4.3 / 3.2 AH | 3.54" x 2.76" x 3.98" | 4.2" | 3.44 lbs | F1 |
| D1272-F1 | 7.2 / 6.8 / 6.2 / 4.5 AH | 5.94" x 2.56" x 3.74" | 4.0" | 4.74 lbs | F1 |
| D1290-F2 | 9 / 8.5 / 7.7 / 5.8 AH | 5.94" x 2.56" x 3.74" | 4.0" | 5.40 lbs | F2 |
| D12120-F2 | 12 / 11.4 / 10.2 / 7.5 AH | 5.94" x 3.86" x 3.74" | 4.0" | 7.61 lbs | F2 |
| D12180-M5 | 18 / 16.2 / 14.5 / 11 AH | 7.13" x 3.03" x 6.57" | 6.6" | 11.24 lbs | M5 |
| D12350-M6 | 35 / 33 / 28.5 / 20 AH | 7.68" x 5.12" x 6.10" | 6.6" | 22.05 lbs | M6 |
Capacity is rated at 30Β°C (86Β°F): 20 Hr and 10 Hr to 1.80 VPC, 5 Hr to 1.75 VPC and 1 Hr to 1.60 VPC.
Choose This Battery When
- You need a reliable backup or standby battery.
- You power medical devices, security and alarm systems, emergency lighting or similar equipment.
- You want a maintenance-free, sealed battery with no watering.
- Your battery stays on a float charger most of the time.
- You need a battery that can sit in storage for a long time.
Consider Another Option When
- Your equipment cycles the battery deeply every day. A deep-cycle or traction battery is a better fit.
- You need a starting (cranking) battery.
- Your equipment needs a voltage, capacity or size not listed above.
- Your equipment needs a different terminal type than the one listed for that model.
- You need a design life longer than 5 years.
Key Features and Benefits
Maintenance-Free AGM Design
The valve-regulated AGM construction is non-spillable and no-gassing, so you never need to water it or check the electrolyte.
Long Design Life
Each battery has an up to 5-year design life in standby service. Its 99% gas recombination helps extend battery life.
Long Shelf Life
Low self-discharge of 2 β 3% per month helps the battery hold its charge in storage.
Wide Operating Temperature
The battery discharges from -40Β°F to 122Β°F and handles low temperatures better than flooded or gel batteries.
Flame Retardant Case
A flame retardant UL94:V0 ABS case and cover is available.
Quick Specifications
| Model | Discover VRLA AGM Float Standby |
|---|---|
| SKU | D650-F1, D680-F1, D6120-F1, D1213-F1, D1250-F1, D1272-F1, D1290-F2, D12120-F2, D12180-M5, D12350-M6 |
| Voltage | 6V or 12V (see Choose Your Model) |
| Capacity | 1.3 β 35 AH @ 20 Hr (varies by SKU) |
| Battery Type | AGM, VRLA |
| Construction | Non-Spillable, Maintenance-Free, No-Gassing |
| Case Material | ABS, with flame retardant UL94:V0 available |
| Dimensions | Varies by SKU (see Choose Your Model) |
| Weight | 1.21 β 22 lbs (varies by SKU) |
| Terminal | F1, F2, M5 or M6 (varies by SKU) |
| Design Life | Up to 5 years |
| Self-Discharge | 2 β 3% per month @ 68Β°F |
| Charge Temperature | 14Β°F to 122Β°F |
| Discharge Temperature | -40Β°F to 122Β°F |
| Storage Temperature | -4Β°F to 140Β°F |
| Standards | IEC 60896-21/22, BS EN 60254-1:2005, UL, CE |
| Watering | No Watering Required |
| Application | Medical Devices, Security Systems, Emergency Lighting & Standby Power |
| Condition | New |
Compatibility and Setup
The Discover VRLA AGM Float Standby battery replaces sealed lead-acid batteries of the same voltage, size and terminal type. Before ordering, use the Choose Your Model table to match your equipment's voltage, capacity, dimensions and terminal.
Charge settings at 77Β°F:
| Charge Setting | 6V Battery | 12V Battery |
|---|---|---|
| Standby / Float Voltage | 6.75 β 6.9V (2.25 β 2.30 VPC) | 13.5 β 13.8V (2.25 β 2.30 VPC) |
| Cyclic Charge Voltage | 7.35V (2.45 VPC) | 14.7V (2.45 VPC) |
For cyclic use, charge to 2.45 VPC and hold until current drops to 1% of the 20-hour rating (0.01C20). Then disconnect the charger or switch it to float.
Need help confirming compatibility? Before ordering, check your equipment make, model, voltage, battery space and terminal type.
Frequently Asked Questions
What is the difference between the models?
They differ in voltage, size, capacity, weight and terminal type. All models share the same AGM technology and features. See the Choose Your Model table to find the right fit.
Does this battery require watering?
No. The sealed VRLA AGM design is maintenance-free and does not need watering.
Is the battery spill-proof?
Yes. The battery is non-spillable and no-gassing.
How long does it last?
Each battery has an up to 5-year design life in standby service.
What charger should I use?
For standby use, hold a constant float voltage of 2.25 β 2.30 volts per cell (13.5 β 13.8V for a 12V battery). For cyclic use, charge to 2.45 volts per cell.
Can I store it?
Yes. Charge stored batteries at least every 6 months to prevent sulfation and permanent capacity loss.
Why Buy From PowRparts?
- Maintenance-free AGM technology
- Non-spillable, no-gassing construction
- Up to 5-year design life
- 10 sizes in 6V and 12V
- Trusted standby power for critical equipment
- Expert support for battery matching
Charging & Maintenance
- Float charge at 2.25 β 2.30 VPC for standby use
- No watering required
- Adjust charge voltage for temperature: +3 mV per cell per Β°F below 77Β°F, and -3 mV per cell per Β°F above 77Β°F
- Charge stored batteries within 6 months to prevent sulfation and permanent capacity loss
Safety features include:
- Non-spillable VRLA AGM construction
- 99% gas recombination
- Flame retardant UL94:V0 ABS case and cover available
- ISO 9001/14001 certified manufacturing facilities
β οΈ WARNING
This product can expose you to chemicals which are known to the State of California to cause cancer and birth defects or other reproductive harm. Use only in well-ventilated areas and with appropriate personal protective equipment.
For more information, visit www.P65Warnings.ca.gov.