Discover DRY CELL AGM Battery 6V & 12V
Discover DRY CELL AGM Traction Industrial Battery β 6V & 12V
SKU: EV627A | EVGC6A | EVGT6A | EV305A | EVU1A | EV34A | EV24A | EV27A | EV31A | EV12A | EV185A
The Discover DRY CELL AGM Traction Industrial battery is a maintenance-free, deep-cycle battery built for floor scrubbers, scissor lifts, pallet jacks, AGVs and other industrial equipment that cycles deeply every shift. It is built to outperform flooded, AGM and gel deep-cycle batteries in demanding traction applications. It delivers long runtimes and high operating current, and it holds up to deep discharges.
- DRY CELL AGM, VRLA technology β maintenance-free, non-spillable and no-gassing
- Available in 11 sizes from 33 AH to 330 AH (20-hour rate)
- 550+ cycles at 70% depth of discharge (IEC 254-1)
- Carbon additives improve partial state of charge performance
- Used and trusted for more than 10 years by the world's largest industrial equipment makers (OEMs)
What It Is
The Discover DRY CELL AGM Traction Industrial battery is a valve-regulated lead-acid (VRLA) deep-cycle battery made for motive power equipment. It uses thick plates with graphite-enhanced alloys for long runtime over its working life. It also uses hydropolymer electrolytes that resist dry-out and prevent thermal runaway.
Unlike standard AGM batteries, DRY CELL handles intense duty cycling, partial state of charge use, overcharge and over-discharge better. It also performs better in high and low temperatures. It works with standard AGM/gel semi-traction charge profiles, and Discover offers specific charge algorithms for the best performance and life.
Choose Your Model
All models share the same DRY CELL AGM technology, features and charging method. They differ in voltage, size, capacity and terminal.
6V Models
| SKU | Industry Reference | Capacity C20 / C5 / C3 | Dimensions (L x W x H) | Weight | Terminal |
|---|---|---|---|---|---|
| EV627A | 627 | 210 / 180 / 165 AH | 12.1" x 6.6" x 8.7" | 64 lbs | M8 |
| EVGC6A | GC2 | 220 / 190 / 170 AH | 10.3" x 7.1" x 10.0" | 65 lbs | AM |
| EVGT6A | GC2H | 260 / 222 / 200 AH | 10.2" x 7.1" x 10.9" | 77 lbs | AM |
| EV305A | 902-305 | 330 / 290 / 260 AH | 11.6" x 7.1" x 13.6" | 101 lbs | AM |
12V Models
| SKU | Industry Reference | Capacity C20 / C5 / C3 | Dimensions (L x W x H) | Weight | Terminal |
|---|---|---|---|---|---|
| EVU1A | U1 | 33 / 30 / 27 AH | 7.7" x 5.1" x 6.7" | 23 lbs | M6 |
| EV34A | 34 | 65 / 55 / 48 AH | 10.2" x 6.6" x 7.2" | 43 lbs | SAE |
| EV24A | 24 | 85 / 72 / 66 AH | 10.2" x 6.8" x 8.4" | 52 lbs | AM |
| EV27A | 27 | 100 / 90 / 80 AH | 12.1" x 6.8" x 8.3" | 63 lbs | AM |
| EV31A | 31 | 120 / 98 / 92 AH | 13.0" x 6.8" x 8.5" | 71 lbs | AM |
| EV12A | 31T | 145 / 125 / 110 AH | 13.0" x 6.8" x 10.3" | 86 lbs | AM |
| EV185A | 921-185 | 230 / 200 / 175 AH | 15.2" x 7.0" x 13.9" | 136 lbs | AM |
Capacity is rated at 25Β°C (77Β°F): C20 to 1.80 VPC, C5 to 1.75 VPC and C3 to 1.70 VPC. Height is case height and does not include terminals.
Choose This Battery When
- You need a deep-cycle battery for equipment that is used several times a day.
- You run floor scrubbers, scissor lifts, aerial work platforms, pallet jacks or AGVs.
- You want a maintenance-free battery with no watering.
- You need a battery that handles deep discharges and partial state of charge use.
- You need a non-spillable, no-gassing battery for indoor or environmentally sensitive areas.
Consider Another Option When
- You need a starting (cranking) battery rather than a deep-cycle battery.
- Your equipment needs lithium, or a voltage or capacity not listed above.
- Your battery space does not fit any of the sizes listed above.
- Your charger cannot be set to an AGM/gel or Discover DRY CELL charge profile.
- Your equipment needs a different terminal type than the one listed for that model.
Key Features and Benefits
Hydropolymer Electrolyte
Organic capillary separators filled with hydropolymer electrolyte hold extra electrolyte volume. This resists dry-out, prevents thermal runaway and keeps performance steady over the battery's life.
Enhanced Alloys
Thick plates with graphite-enhanced alloys deliver maximum runtime over the battery's working life.
Carbon Boost
Carbon additives improve duty cycle performance, charge acceptance and partial state of charge operation.
Long Cycle Life
The battery is rated for 550+ cycles at 70% depth of discharge (IEC 254-1) and 350+ cycles at 100% depth of discharge (DIN 43 539). Discover rates its life above flooded, gel and AGM deep-cycle batteries.
Built for Tough Conditions
It is shock and vibration tested to IEC 61373, DIN EN 61373 and SAE J537. It discharges in temperatures from -40Β°F to 122Β°F.
Safe and Maintenance-Free
The battery is non-spillable and no-gassing. Pressure relief valves reduce water loss, integrated flame arrestors help prevent fire and explosion, and the battery is spark and explosion tested (SAE J1495).
Quick Specifications
| Model | Discover DRY CELL AGM Traction Industrial |
|---|---|
| SKU | EV627A, EVGC6A, EVGT6A, EV305A, EVU1A, EV34A, EV24A, EV27A, EV31A, EV12A, EV185A |
| Voltage | 6V or 12V (see Choose Your Model) |
| Capacity | 33 β 330 AH @ 20 Hr (varies by SKU) |
| Battery Type | DRY CELL AGM, VRLA |
| Construction | Non-Spillable, Maintenance-Free, No-Gassing |
| Case Material | Polypropylene (key models) |
| Dimensions | Varies by SKU (see Choose Your Model) |
| Weight | 23 β 136 lbs (varies by SKU) |
| Terminal | M6, M8, AM or SAE (varies by SKU) |
| Cycle Life | 550+ cycles @ 70% DoD / 350+ cycles @ 100% DoD |
| Self-Discharge | 2 β 3% per month @ 68Β°F |
| Charge Temperature | 14Β°F to 122Β°F |
| Discharge Temperature | -40Β°F to 122Β°F |
| Storage Temperature | -4Β°F to 140Β°F |
| Standards | IEC 60254-1, DIN 43 539, SAE J537, SAE J1495, UL, CE |
| Watering | No Watering Required |
| Application | Floor Scrubbers, Scissor Lifts, Pallet Jacks, AGVs & Industrial Equipment |
| Condition | New |
Compatibility and Setup
The Discover DRY CELL AGM Traction Industrial battery replaces standard deep-cycle batteries in the industry sizes listed above. Before ordering, use the Choose Your Model table to match your equipment's voltage, battery size, capacity and terminal type. Then check your battery compartment dimensions and minimum battery weight.
Discover recommends a constant current (IUI) charger for traction equipment with deep discharges, like floor scrubbers and material handling equipment. For a voltage regulated (IUU) charger, use these settings at 77Β°F:
| Charge Setting | 6V Battery | 12V Battery |
|---|---|---|
| Bulk & Absorption Voltage | 7.4V | 14.7V |
| Float Voltage | 6.8V | 13.6V |
| Recommended Charge Current | 10% β 25% of C20 rating | 10% β 25% of C20 rating |
Need help confirming compatibility? Before ordering, check your equipment make, model, voltage, battery compartment dimensions and charger settings.
Frequently Asked Questions
What is the difference between the models?
They differ in voltage, size, capacity, weight and terminal type. All models share the same DRY CELL AGM technology and features. See the Choose Your Model table to find the right fit.
Does this battery require watering?
No. The VRLA DRY CELL AGM design is maintenance-free and does not need watering.
Is the battery spill-proof?
Yes. The battery is non-spillable and no-gassing, so it is safe for indoor and environmentally sensitive areas.
How is it different from a standard AGM battery?
DRY CELL uses thicker plates, carbon additives and hydropolymer electrolyte. Discover rates it above standard AGM for cycle life, partial state of charge use, high-temperature life and vibration resistance.
What charger should I use?
Use a charger with an AGM/gel semi-traction profile or a Discover DRY CELL profile. Discover recommends an IUI charge algorithm for deep-discharge traction applications.
How deeply can I discharge it?
Discover recommends setting the low voltage disconnect to 1.90 volts per cell, which limits discharge to 80%. This helps the battery last longer.
Why Buy From PowRparts?
- Maintenance-free DRY CELL AGM technology
- Non-spillable, no-gassing construction
- Long cycle life for daily deep-cycle use
- 11 sizes in 6V and 12V
- Trusted by leading industrial equipment makers
- Expert support for battery and charger matching
Charging & Maintenance
- Charge with an AGM/gel semi-traction or Discover DRY CELL charge profile
- No watering required
- Adjust charge voltage for temperature: +3 mV per cell per Β°F below 77Β°F, and -3 mV per cell per Β°F above 77Β°F
- Top charge stored batteries within 6 months to prevent sulfation and permanent capacity loss
- Set the low voltage disconnect to 1.90 VPC to limit discharge to 80%
Safety features include:
- Non-spillable VRLA DRY CELL AGM construction
- Pressure relief valves
- Integrated flame arrestors
- Spark and explosion tested (SAE J1495)
- ISO 9001/14001 certified manufacturing facilities
β οΈ WARNING
This product can expose you to chemicals which are known to the State of California to cause cancer and birth defects or other reproductive harm. Use only in well-ventilated areas and with appropriate personal protective equipment.
For more information, visit www.P65Warnings.ca.gov.